Fault Location Identification for Ring and Radial Power Distribution Network with Optimally Placed PMU’s
Abstract
Synchrophasor measurements from phasor measurement units (PMUs) will help network operators in many tasks including optimization of power flow, controlling power systems, contingency analysis, detection of fault etc. To achieve these, there is no requirement of PMUs to be placed in all the nodes of power network. In this paper, binary based search algorithm is used for optimal placement of PMUs and tested in different IEEE standard networks. After optimal placement of PMUs, next phase is the identification of fault location. The suggested scheme for fault location identification technique consists of three parallel paths which will be running concurrently. From the outputs of these parallel steps, the possible fault point can be determined. The proposed scheme has been tested using PSS®E & MATLAB to provide 98% precise results in the selected line span.
Keywords
Full Text:
PDFReferences
J. De La Ree, V. Centeno, J. S. Thorp and A. G. Phadke, "Synchronized Phasor Measurement Applications in Power Systems," in IEEE Transactions on Smart Grid, Vol. 1, No. 1, pp. 20-27, June 2010, DOI: 10.1109/TSG.2010.2044815.
IEEE Standard for Synchrophasors for Power Systems," in IEEE Std C37.118-2005 (Revision of IEEE Std 1344-1995), vol., no., pp.1-65, 22 March 2006, DOI: 10.1109/IEEESTD.2006.99376.
L. Jiaping and H. Cheng” Wide-area monitoring protection and control of future power system networks”, In: Proc. of 2014 IEEE “Workshop on Advanced Research and Technology in Industry Applications” (WARTIA), 2014; 903-905.
B. Singh, N. Sharma, A. Tiwari, K. Verma and S. Singh, “Applications of phasor measurement units (PMUs) in electric power system networks incorporated with FACTS controllers,” International Journal of Engineering, Science and Technology, Vol. 3, pp. 64-82, 2011, DOI:10.4314/ijest.v3i3.68423
V.K.Agrawal, P.K.Agarwal, Rajesh Kumar, “Experience of commissioning of PMUs Pilot Project in the Northern Region of India”, 16th National Power Systems Conference, December, 2010.
G. Chugulu, F. Simba, and K. Suzan Lujara, “Proposed Practical Communication Architecture for Automatic Fault Detection and Clearance in Secondary Distribution Power Network,” International Journal of Smart Grid, Vol. 4, No. 4, December, 2020.
D. Motyka, M. Kajanová and P. Braciník, "The Impact of Embedded Generation on Distribution Grid Operation," 2018 7th International Conference on Renewable Energy Research and Applications (ICRERA), 2018, pp. 360-364, DOI: 10.1109/ICRERA.2018.8566741.
Zuyi Li and Jiachun Guo, "Wisdom about age [aging electricity infrastructure]," in IEEE Power and Energy Magazine, vol. 4, no. 3, pp. 44-51, May-June 2006, DOI: 10.1109/MPAE.2006.1632453..
Y. Mizuno, Y. Tanaka, F. Kurokawa and N. Matsui, "A Modelling for an Optimum Facility Design in a Clinic as a Smart Grid," 2021 9th International Conference on Smart Grid (icSmartGrid), 2021, pp. 149-153, DOI: 10.1109/icSmartGrid52357.2021.9551217.
R. E. Brown and B. G. Humphrey, "Asset management for transmission and distribution," in IEEE Power and Energy Magazine, vol. 3, no. 3, pp. 39-45, May-June 2005, DOI: 10.1109/MPAE.2005.1436499.
D. Chouhan and V. Jaiswal “A literature review on optimal placement of PMU and voltage stability”. “Indian Journal of Science and Technology”, 2016; 9(47), DOI: 10.17485/ijst/2016/v9i47/101724
M. Sefid and M. Rihan, “Optimal PMU placement in a smart grid: An updated review,” International Journal. of Smart Grid and Clean Energy, Vol. 8, pp. 59-69, January. 2019, DOI:10.12720/sgce.8.1.59-69
A. Chowdhury, N. Sahu and Shimi S.L, “Optimal PMU Placement in 14 Bus System using Integer Linear Programming,” International Journal of Advanced Research in Computer and Communication.. Eng., Vol. 6, pp. 28-31, February 2017.
M. Mirzaei, M. Kadir, E. Moazami and H. Hizam, “Review of Fault Location Methods for Distribution Power System,” Australian Journal of Basic and Applied Sciences, Vol. 3, pp. 2670- 2676, 2009
J. Zhu, D. L. Lubkeman and A. A. Girgis, "Automated fault location and diagnosis on electric power distribution feeders," in IEEE Transactions on Power Delivery, vol. 12, no. 2, pp. 801-809, April 1997, DOI: 10.1109/61.584379.
J. Ren, S. S. Venkata and E. Sortomme, "An Accurate Synchrophasor Based Fault Location Method for Emerging Distribution Systems," in IEEE Transactions on Power Delivery, vol. 29, no. 1, pp. 297-298, Feb. 2014, DOI: 10.1109/TPWRD.2013.2288006.
Z. Zhou, W. Gao and Y. Zhang, “Research on ?PMU based fault location for active distribution network,” International Forum on Energy, Environment Science and Materials, pp. 629-632, 2015, DOI: 10.2991/ifeesm-15.2015.119
V. Junior Foba Kakeu, A. Teplaira Boum and K. C. Franklin Mbey, “Optimal Reliability of a Smart Grid,” International Journal of Smart Grid, Vol. 5, No. 2, June, 2021
A. Bitebo, G. Chugulu, D. Makota and F. Simba, "A Proposed Secure Hybrid, Hierarchical Communication Architecture to Facilitate Fault Prediction in SDPN," 2021 9th International Conference on Smart Grid (icSmartGrid), 2021, pp. 107-111, DOI: 10.1109/icSmartGrid52357.2021.9551256.
M. Zhang, Y. Wang, Z. Zhou and Z. Li, "Research on fault location based on PMU for multi-source distribution network," 2016 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC), 2016, pp. 1877-1882, DOI: 10.1109/APPEEC.2016.7779815.
J. Mora-Florez, J. Melendez and G. Garrillo-Caiecedo, “Comparison of impedance based fault location methods for power distribution systems,” Electric Power Systems Research, Vol. 78, No. 4, pp. 657-666, April. 2008, DOI: 10.1016/j.epsr.2007.05.010
F. C. L. Trindade, W. Freitas and J. C. M. Vieira, "Fault Location in Distribution Systems Based on Smart Feeder Meters," in IEEE Transactions on Power Delivery, vol. 29, no. 1, pp. 251-260, Feb. 2014, DOI: 10.1109/TPWRD.2013.2272057.
H. Bakiri, H. Maziku, K. Nerey Mvungi, N. Hamisi and M. Libe “A Novel Load Forecasting Model for Automatic Fault Clearance in Secondary Distribution Electric Power Grid using an Extended-Multivariate Nonlinear Regression,” International Journal of Smart Grid, Vol. 5, No. 2, June, 2021
R. A. F. Pereira, L. G. W. da Silva, M. Kezunovic and J. R. S. Mantovani, "Improved Fault Location on Distribution Feeders Based on Matching During-Fault Voltage Sags," in IEEE Transactions on Power Delivery, vol. 24, no. 2, pp. 852-862, April 2009, DOI: 10.1109/TPWRD.2009.2014480.
J. Teng, W. Huang and S. Luan, "Automatic and Fast Faulted Line-Section Location Method for Distribution Systems Based on Fault Indicators," in IEEE Transactions on Power Systems, vol. 29, no. 4, pp. 1653-1662, July 2014, DOI: 10.1109/TPWRS.2013.2294338.
L. Ibarra, J. Avilés, D. Guillen, J. C. Mayo-Maldonado, J. E. Valdez-Resendiz and P. Ponce, “Optimal micro-PMU placement and virtualization for distribution network changing topologies,” Elsevier, Sustainable Energy, Grids and Networks Vol. 27, September 2021, 100510, DOI: 10.1016/j.segan.2021.100510
X. Huang, Z. Xie and X. Huang, "Fault Location of Distribution Network Base on Improved Cuckoo Search Algorithm," in IEEE Access, vol. 8, pp. 2272-2283, 2020, DOI: 10.1109/ACCESS.2019.2962276..
M. Pooria, M. Shahab and N. Hamidreza, "Sensitivity analysis-based optimal PMU placement for fault observability", IET Generation Transmission & Distribution, Vol. 15, No. 4, pp. 737-750, 2020, DOI: 10.1049/gtd2.12055
M. H. Rezaeian Koochi, P. Dehghanian and S. Esmaeili, "PMU Placement With Channel Limitation for Faulty Line Detection in Transmission Systems," in IEEE Transactions on Power Delivery, vol. 35, no. 2, pp. 819-827, April 2020, DOI: 10.1109/TPWRD.2019.2929097.
M. Netto, V. Krishnan, Y. Zhang and L. Mili, "Measurement placement in electric power transmission and distribution grids: Review of concepts methods and research needs", IET Generation, Transmission & Distribution, Vol. 16, pp. 805, 2022, DOI:10.1049/gtd2.12336
B. Ben Jose, A. Gounden and N. Vasanth, “Hybrid power electronic controller for combined operation of constant power and maximum power point tracking for single-phase grid-tied photovoltaic systems”, IET Power Electronics, Vol. 7, No. 12, pp. 3007-3016, December 2014. DOI:10.1049/iet-pel.2013.0974.
DOI (PDF): https://doi.org/10.20508/ijrer.v12i3.13038.g8558
Refbacks
- There are currently no refbacks.
Online ISSN: 1309-0127
Publisher: Gazi University
IJRER is cited in SCOPUS, EBSCO, WEB of SCIENCE (Clarivate Analytics);
IJRER has been cited in Emerging Sources Citation Index from 2016 in web of science.
WEB of SCIENCE in 2025;
h=35,
Average citation per item=6.59
Last three Years Impact Factor=(1947+1753+1586)/(146+201+78)=5286/425=12.43
Category Quartile:Q4